PULSE=DISABLE_SINGLE_PULSE, EDGE=NO_EDGE_DETECTION, SELECT=CTOUT_6_OR_T1_MAT2, INV=NOT_INVERTED, SYNCH=DISABLE__SYNCHRONIZ
Event router input 14 multiplexer (GIMA output 26)
INV | Invert input 0 (NOT_INVERTED): Not inverted. 1 (INPUT_INVERTED): Input inverted. |
EDGE | Enable rising edge detection 0 (NO_EDGE_DETECTION): No edge detection. 1 (RISING_EDGE_DETECTIO): Rising edge detection enabled. |
SYNCH | Enable synchronization 0 (DISABLE__SYNCHRONIZ): Disable synchronization. 1 (ENABLE__SYNCHRONIZA): Enable synchronization. |
PULSE | Enable single pulse generation. 0 (DISABLE_SINGLE_PULSE): Disable single pulse generation. 1 (ENABLE_SINGLE_PULSE): Enable single pulse generation. |
SELECT | Select input. Values 0x3 to 0xF are reserved. 0 (CTOUT_6_OR_T1_MAT2): CTOUT_6 or T1_MAT2 1 (SGPIO12): SGPIO12 2 (T1_MAT2): T1_MAT2 |
RESERVED | Reserved |